Protégé® SE Integrated System ControllerInstallaon ManualPRT-CTRL-SEPENDING
74.4 Baery Backup It is recommended that a minimum of a 4Ah baery is used as the main baery backup. From the accessory bag provided, connect the re
84.5 Baery Charge Current Seng To congure the Protégé® SE Integrated System Controller manually for the charge current, select the appropriate bae
94.7 Encrypted Module Network The Protégé® SE Integrated System Controller incorporates technically advanced encrypted RS-485 communicaons technology
10Figure 10 - EOL JumperAlways connect the Protégé® SE Integrated System Controllers NA and NB terminals to the NA and NB terminals of the expansion d
114.8 Telephone Dialer The Protégé® SE Integrated System Controller provides the ability to communicate alarms and upload/download informaon with rem
124.9 Expansion Connector The Protégé® SE Integrated System Controller has an onboard expansion connector that is used to connect serial communicaon,
134.10 Ethernet 10/100 Network Interface The communicaon between the Protégé® System and the Protégé® SE Integrated System Controller uses a 10/100 E
145.0 Door Access ControlThe Protégé® SE Integrated System Controller provides Access control funconality onboard without the requirement for addion
155.2 Mulple Wiegand Card Reader Connecon When operang the Protégé® SE Integrated System Controller in Mulple Reader mode the Protégé® SE Integrat
165.3 Door Contact Connecon The Protégé® SE Integrated System Controller allows the connecon of up to 4x contacts for monitoring and controlling acc
The specicaons and descripons of products and services contained in this manual were correct at the me of prinng. Integrated Control Technology L
175.4 Lock Output Connecon The Protégé® SE Integrated System Controller provides a connecon for 2x electric strike locks with full monitoring of the
185.5 Programming the Onboard Reader The onboard reader is programmed in exactly the same way as any other reader module is. It can be though of as if
19!The zones 9-12 and 13-16 can operate as either general purpose zone inputs or as onboard reader inputs. If used as general purpose zone inputs then
20Each zone input can use a dierent input conguraon. To program a large number of zones with a certain conguraon use the Mulple Selecon feature
216.3 Trouble Zones Each Protégé® SE Integrated System Controller can monitor up to 64 local trouble zones. Trouble zones are used to monitor the stat
227.0 Programmable OutputsThe Protégé® SE Integrated System Controller has 8x Programmable Outputs (PGM’s). The PGM’s are used to acvate sirens, bell
237.2 PGM 3/4 Outputs The PGM Outputs 3 (PGM3 CP001:03) and 4 (PGM4 CP001:04) on the Protégé® SE IntegratedSystem Controller are Open Collector Output
24Figure 25 - Conguraon Switch8.0 Hardware Conguraon 8.1 Conguraon SwitchThe Protégé® SE Integrated System Controller uses a 4 way dual in line
258.2 Defaulng a Controller The Protégé® SE Integrated System Controller can be set back to factory default using the following procedures. This will
269.0 LED Indicators The Protégé® SE Integrated System Controller includes extensive diagnosc indicators that can aid the installer in diagnosing fau
Table of Contents1.0 Welcome ...
279.7 Bell 1/Bell 2 Indicators The Bell 1/Bell 2 Indicators will show the status of the Bell Output and the over current or circuit fault condions.9.
2810.0 Mechanical DiagramThe mechanical diagram shown below outlines the essenal details needed to help ensure the correct installaon of the Protégé
2911.0 Mechanical LayoutThe mechanical layout shown below outlines the essenal details needed to help ensure the correct installaon of the Protégé®
3012.0 System CapaciesThe Protégé® SE Integrated System Controller can be proled to allow a comprehensive soluon that allows opmal performance to
3113.0 Technical SpecicaonsThe following technical specicaons are important and vital to the correct operaon of the Protégé® SE Integrated System
32?The isolated communicaons interface on the Protégé® SE Integrated SystemController uses full galvanic isolaon to prevent ground loop noise and cr
!It is important that the unit when installed is located in a dry cool locaon that is not aected by humidity. Do not locate the unit in an air condi
3413.3 Current and Validaon Example 3The example shown below refers to the specicaon’s table needed to help ensure the correct installaon of the P
3514.0 Ordering InformaonPlease use the following product codes when placing an order for the Protégé® SE Integrated System Controller. • PRT-CTRL-S
3615.0 WarrantyThe Seller warrants its products to be free from defects in materials and workmanship under normal use for a period of one year. Excep
9.0 LED Indicators ...26 9.1 Statu
Integrated Control Technology Limited11 Canaveral Drive, Albany, North Shore City 0632, Auckland, New Zealand P.O. Box 302-340, North Harbour, Aucklan
1.0 Welcome!Thank you for purchasing the Protégé® SE Integrated System Controller by Integrated Control Technology. The Protégé® System is an advanced
2.0 Protégé® System Management Suite The Protégé® System Management Suite applicaon is a Windows®™ based Integrated Access Control and Alarm Manageme
3.0 MounngThe Protégé® SE Integrated System Controller is supplied as a PCB only (Printed Circuit Board). It is recommended that the gear plate style
54.0 Connecons 4.1 Cabinet Enclosure Tamper SwitchThe cabinet enclosure tamper input signals to the monitoring staon or remote computer that an cabi
64.3 AC PowerThe Protégé® SE Integrated System Controller should be supplied by a dedicated electrical power source rated for a minimum 10Amp load and